Tensile stress distribution in maxillary central incisors restored with cast-made and prefabricated dental posts.
Abstract
Abstract: Aim: To analyze and compare the tensile stress distribution in endodontically treated teeth restored with cast-made (Ni-Cr and gold) and prefabricated (titanium and glass fibre) dental posts. Methodology: Four three-dimensional finite element (FE) models of a maxillary central incisor restored with Ni-Cr cast-made (Model Ni-Cr), gold cast-made (Model GO), prefabricated titanium (Model TI) and prefabricated glass fibre (Model FP) posts were constructed. An oblique loading of 100N was applied to each three-dimensional model. Tensile stress distribution within the root dentine and at the post and surrounding structure interfaces were analysed. Results: In all the FE models studied, a higher magnitude of tensile stresses was observed on the palatal aspect of the cervical dentin as compared to the labial aspect and progressively decreases from the outer to the inner part of the root. The gold cast-made and glass fibre post models showed significantly less tensile stress concentration in the post-core component than the other experimental models. The maximum tensile stress was seen on the palatal aspect of the Ni-Cr compared to other posts. The higher magnitude interfacial tensile stress concentration was observed in a pulpless tooth restored with a Ni-Cr cast-made post, followed by titanium and gold cast-made posts, respectively. However, the minimum interfacial tensile stress was noticed in a pulpless tooth restored with a glass fibre post. Conclusion: Glass fibre posts tend to transfer tensile stress more homogenously within the tooth and at interfaces than the other types of investigated posts.References
2. Madfa AA, Al-Sanabani FA, Al-Qudaimi NH. Effect of Post Materials on the Biomechanical Behaviour of Endodontically Treated Tooth. Int J Med Imaging. 2014;2(3):54–8.
3. Kainose K, Nakajima M, Foxton R, Wakabayashi N, Tagami J. Stress distribution in root filled teeth restored with various post and core techniques: effect of post length and crown height. Int Endod J. 2015;48(11):1023–32.
4. Eliyas S, Jalili J, Martin N. Restoration of the root canal treated tooth. Br Dent J. 2015;218(2):56–62.
5. Merdji A, Bouiadjra BB, Chikh BO, Mootanah R, Aminallah L, Serier B, Muslih IM. Stress distribution in dental prosthesis under an occlusal combined dynamic loading. Mater Des. 2012;36:705–13.
6. Ferrari M, Vichi A, Fadda GM, Cagidiaco MC, Tay FR, Breschi L, Polimeni A, Goracci C. A randomized controlled trial of endodontically treated and restored premolars. J Dent Res. 2012;91(7 Suppl):72S–78S.
7. Torbjörner A, Fransson B. Biomechanical aspects of prosthetic treatment of structurally compromised teeth. Int J Prosthodont. 2004;17(2):135–41.
8. Madfa AA, Al-Hamzi MA, Al-Sanabani FA, Al-Qudaimi NH, Yue XG. 3D FEA of cemented glass fiber and cast posts with various dental cements in a maxillary central incisor. Springerplus. 2015;4:598.
9. Morresi AL, D’Amario M, Capogreco M, Gatto R, Marzo G, D’Arcangelo C, Monaco A. Thermal cycling for restorative materials: does a standardized protocol exist in laboratory testing? A literature review. J Mech Behav Biomed Mater. 2014;29:295–308.
10. Sharafeddin F, Alavi AA, Zare S. Fracture resistance of structurally compromised premolar roots restored with single and accessory glass or quartz fiber posts. Dent Res J. 2014;11(2):264–70.
11. Shetty PP, Meshramkar R, Patil KN, Nadiger RK. A finite element analysis for a comparative evaluation of stress with two commonly used esthetic posts. Eur J Dent. 2013;7(4):419–22.
12. Er O, Kilic K, Esim E, Aslan T, Kilinc HI, Yildirim S. Stress distribution of oval and circular fiber posts in amandibular premolar: a three-dimensional finite element analysis. J Adv Prosthodont. 2013;5(4):434–9.
13. Lazari PC, Oliveira RC, Anchieta RB, Almeida EO, Freitas Junior AC, Kina S, Rocha EP. Stress distribution on dentin-cement-post interface varying root canal and glass fiber post diameters. A three-dimensional finite element analysis based on micro-CT data. J Appl Oral Sci. 2013;21(6):511–7. [PubMed]
14. Lü LW, Meng GW, Liu ZH. Finite element analysis of multi-piece post-crown restoration using different types of adhesives. Int J Oral Sci. 2013;5(3):162–6. [PubMed]
15. Romeed SA, Dunne SM. Stress analysis of different post-luting systems: a three-dimensional finite element analysis. Aust Dent J. 2013;58(1):82–8.
16. Cicciu M, Bramanti E, Matacena G, Guglielmino E, Risitano G. FEM evaluation of cemented-retained versus screw-retained dental implant single-tooth crown prosthesis. Int J Clin Exp Med. 2014;7(4):817–25.
17. Bessone L, Bodereau E, Cabanillas G, Dominguez A. Analysis of biomechanical behaviour of anterior teeth using two different methods: Finite element method and experimental tests. Engineering. 2014;6(3):148–58.
18. Kaur J, Verma PR, Sharma N, Kinra M. Review of Stresses around Post Restorations – An Insight View through Finite Element Analysis. IOSR J Dent Med Sci. 2015;14(2):75–9.
19. Kumar P, Rao RN. Three-dimensional finite element analysis of stress distribution in a tooth restored with metal and fiber posts of varying diameters: An in-vitro study. J Conserv Dent. 2015;18(2):100–4.
20. Kainose K, Nakajima M, Foxton R, Wakabayashi N, Tagami J. Stress distribution in root filled teeth restored with various post and core techniques: effect of post length and crown height. Int Endod J. 2015;48(11):1023–32.
21. Erdemir A, Guess TM, Halloran J, Tadepalli SC, Morrison TM. Considerations for reporting finite element analysis studies in biomechanics. J Biomech. 2012;45(4):625–33.
22. Pérez-González A, Iserte-Vilar JL, González-Lluch C. Interpreting finite element results for brittle materials in endodontic restorations. Biomed Eng Online. 2011;10:44.
23. Lanza A, Aversa R, Rengo S, Apicella D, Apicella A. 3D FEA of cemented steel, glass and carbon posts in a maxillary incisor. Dent Mater. 2005;21(8):709–15.
24. Pegoretti A, Fambri L, Zappini G, Bianchetti M. Finite element analysis of a glass fibre reinforced composite endodontic post. Biomaterials. 2002;23(13):2667–82.
25. Kinney JH, Marshall SJ, Marshall GW. The mechanical properties of human dentin: a critical review and re-evaluation of the dental literature. Crit Rev Oral Biol Med. 2003;14(1):13–29.
26. Upadhyaya V, Bhargava A, Parkash H, Chittaranjan B, Kumar V. A finite element study of teeth restored with post and core: Effect of design, material, and ferrule. Dent Res J. 2016;13(3):233–8.
27. Mahmoudi M, Saidi AR, Amini P, Hashemipour MA. Influence of inhomogeneous dental posts on stress distribution in tooth root and interfaces: Three-dimensional finite element analysis. J Prosthet Dent. 2017:pii:S0022–3913.
28. Amarante MV, Pereira MV, Darwish FA, Camarão AF. Virtual analysis of stresses in human teeth restored with esthetic posts. Mat Res. 2008;11(4):459–63.
29. Al-Omiri MK, Rayyan MR, Abu-Hammad O. Stress analysis of endodontically treated teeth restored with post-retained crowns: A finite element analysis study. J Am Dent Assoc. 2011;142(3):289–300.
30. Silva NR, Castro GG, Santos-Filho PC, Silva GR, Campos RE, Soares PV, Soares CJ. Influence of different post design and composition on stress distribution in maxillary central incisor: Finite element analysis. Indian J Dent Res. 2009;20(2):153–8.
Keywords
This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY 4.0). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. © 2024.